2.14 AT^SCFG
Parameter Description
(str)(+CSCS)
<AutoExecCmd>
AutoExec Command
This parameter serves to switch the Autoexec function on or off.
If it is switched off (<AutoExecCmd>=0), parameters following
at the given index are restored to their default values.
Value will be saved while switching off the TC63 via AT commands (e.g.
on next power up.
"0"
"1"
(str)(+CSCS)
<AutoExecType>
AutoExec Event Type
This parameter selects the kind of event used to automatically launch the AT command(s) specified with
<AutoExecATC>.
Value will be saved while switching off the TC63 via AT commands (e.g.
on next power up.
"0"
"1"
(str)(+CSCS)
<AutoExecIndex>
AutoExec Command Index
This parameter specifies the command storage index. The following table shows the index ranges supported for
each variant of <AutoExecType>.
Value will be saved while switching off the TC63 via AT commands (e.g.
on next power up.
value
<AutoExecType>
0
1
(str)(+CSCS)
<AutoExecMode>
AutoExec Command Mode
0...255
This parameter specifies details regarding the behavior of the TC63 when the AT command starts to be exe-
cuted.
Value is interpreted as a bit field, unused bits are reserved for future use (RFU) and shall be set to 0.
When a call is released by an Autoexec activity, no release indication may be issued on the first logical channel.
If during a data call the TC63 temporarily enters command mode via
specifies 'Ignore ongoing calls'.
<AutoExecMode>
Value will be saved while switching off the TC63 via AT commands (e.g.
on next power up.
TC63_ATC_V00.490
Confidential / Draft - Do not copy
Disable automatic execution of the AT command(s) specified with
at a given <AutoExecIndex>.
ecATC>
Enable automatic execution of the AT command(s) specified with
at a given <AutoExecIndex>. Not allowed for <AutoExecType>=0
cATC>
(DTR line activation) while multiplex mode is active, refer to AT+CMUX.
Autoexec activity is driven by ASC0 DTR line activation (OFF-ON transition).
Autoexec activity is timer driven. To specify the time span use
riod>.
<AutoExecType>
Autoexec activity is driven by ASC0 DTR
line activation
Autoexec activity is timer driven.
Page 56 of 501
are ignored and all settings
<AutoExecIndex>
or AT^SMSO) and restored
AT+CFUN
or AT^SMSO) and restored
AT+CFUN
or AT^SMSO) and restored
AT+CFUN
event
no AT command will be executed if
+++
or AT^SMSO) and restored
AT+CFUN
s
<AutoEx-
<AutoExe-
<AutoExecPe-
Valid Indices
0
0-2
5/24/05