dead interval—This interval should be a multiple of the hello interval.
●
wait timer interval—This interval is required by the OSPF standard to be equal to the router dead
●
interval. Under some circumstances, setting the wait interval to smaller values can help OSPF routers
on a broadcast network to synchronize more quickly at the expense of possibly electing an incorrect
DR or BDR. This value should not be set to less than the hello interval. The default value is equal to
the router dead interval.
Example
The following command sets the timers in area 0.0.0.2:
configure ospf area 0.0.0.2 timer 10 1 20 200
History
This command was first available in ExtremeWare XOS 10.1.
Platform Availability
This command is available on all platforms.
ExtremeWare XOS 11.3 Command Reference
configure ospf area timer
1301
Need help?
Do you have a question about the ExtremeWare XOS and is the answer not in the manual?