5
ZEUS-1004
ZEUS-1004
Message
S<slot number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Reboot the system at the next maintenance window. If the problem persists, replace the blade.
Action
ZEUS-1005
Message
S<slot number>,C<chip index>,A<zeus id>: Memory allocation failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a memory allocation failure in the software.
Recommended
Restart the system at the next maintenance window. If the problem persists, replace the control
Action
processor (CP) blade.
ZEUS-1015
Message
Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the port was re-initialized due to link reset failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
890
Fabric OS Message Reference
53-1002749-01
Need help?
Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?
Questions and answers