5
EM-1014
EM-1014
Message
Unable to read sensor on <FRU Id> (<Return code>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Reseat the FRU. If the problem persists, replace the FRU.
Action
EM-1015
Message
Warm recovery failed (<Return code>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Monitor the switch. If the problem persists, restart or power cycle the switch.
Action
EM-1016
Message
Cold recovery failed (<Return code>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Monitor the switch.
Action
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.