5
AN-1010
AN-1010
Message
Severe latency bottleneck detected at slot <slot number> port <port number within
slot number>.
Message Type
LOG | AUDIT
Class
FABRIC
Severity
WARNING
Probable Cause
Indicates credit loss at the specified port, a downstream port, or a very high latency device at the edge of
the fabric.
Recommended
Contact your switch service provider for assistance.
Action
AN-1011
Message
Could not distinguish between primary and dependent severe latency bottleneck on
slot <slot number> port <port number within slot number> because port mirroring is
enabled on this port.
Message Type
LOG | AUDIT
Class
FABRIC
Severity
WARNING
Probable Cause
Indicates that resources that are needed to determine whether there is complete credit loss on a virtual
channel (VC) at the specified port are used by port mirroring.
Recommended
Contact your switch service provider for assistance.
Action
AN-1012
Message
Credits did not return from other end. Complete loss of credits on a VC on slot
<slot number> port <port number within slot number>.
Message Type
LOG | AUDIT
Class
FABRIC
Severity
WARNING
Probable Cause
Indicates a credit loss.
Recommended
If this message is not followed by the AN-1013 message, contact your switch service provider for
Action
assistance.