Brocade Communications Systems StoreFabric SN6500B Reference page 149

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

AG-1018
Message
Host port should not be connected to port <port number> which is configured as
N_Port.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an initiator or target port is erroneously connected to a port configured for N_Port
operation.
Recommended
Execute the switchShow command to display the status of all ports in the system. Execute the
Action
portCfgShow command to display the list of ports currently configured as N_Ports. Make sure the host
is connected to an F_port.
AG-1019
Message
Unable to failover N_Port <port number>. No other N_Port in port group:<pgid> is
online.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that failover across port groups is not supported.
Recommended
Check whether an alternate N_Port is configured in the specified port group using the ag --pgshow
Action
command.
AG-1020
Message
F_Ports to N_Ports route/mapping has been changed.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that F_Port-to-N_Port mapping has been changed because the switch has come online or
some new N_Ports or F_Ports have come online.
Recommended
Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
Action
Fabric OS Message Reference
53-1002749-01
5
AG-1018
127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents