Configuring system messages and attributes
This section provides information on configuring the system message logs and its attributes. All
admin-level commands mentioned in this section are used to enable or disable only the external
messages.
Configuring event auditing
To configure event auditing, perform the following steps.
1. Log in to the switch as admin.
2. Execute the auditCfg
3. Execute the auditCfg
4. Execute the auditCfg
Fabric OS Message Reference
53-1002749-01
For example, execute the following command to display the documentation for PS-1007.
switch:admin> rasman PS-1007
Log Messages
MESSAGE
PS-1007
-
Failed
domain=<domain id>. <function name>.
MESSAGE TYPE
LOG
SEVERITY
WARNING
PROBABLE CAUSE
Indicates that FC Routing (FCR) is enabled on the
fabric.
RECOMMENDED ACTION
Top Talker cannot be installed on a fabric with FCR
enabled.
In
case Top Talker must be installed on a fabric,
disable FCR using the fosconfig --disable fcr command.
enable command to enable the audit feature.
--
switch:admin> auditcfg --enable
Audit filter is enabled.
class command to configure the event classes you want to audit.
--
switch:admin> auditcfg --class 1,2,3,4,5,6,7,8
Audit filter is configured.
NOTE
The class option 9 (MAPS) is for internal use only. The RAS class is not configurable, and it is
always enabled internally.
severity severity level command if you want to set the Audit severity
--
level. By default, all messages are logged. When the severity is set, only messages with the
configured severity and higher are displayed. Valid values for severity level are INFO, WARNING,
ERROR, and CRITICAL
switch:admin> auditcfg --severity ERROR
Configuring system messages and attributes