Brocade Communications Systems StoreFabric SN6500B Reference page 513

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

FW-1319
Message
<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of SCSI Enclosure Services (SES) violations has changed from a value
outside of the acceptable range to a value within the acceptable range. SES violations indicate that a
Small Computer System Interface (SCSI) Enclosure Services (SES) request has been received from an
unauthorized World Wide Name (WWN). The SES_POLICY contains a list of WWNs of device ports that
are allowed to access the SES Server functionality.
Recommended
No action is required.
Action
FW-1320
Message
<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of Management Server (MS) violations has changed. MS violations indicate
that an MS access request has been received from an unauthorized World Wide Name (WWN). The
MS_POLICY contains a list of WWNs of device ports that are allowed to access the Management Server
functionality.
Recommended
Execute the errShow command to determine the WWN of the device that sent the request. Responses
Action
to security-class messages depend on user policies. Consult your security administrator for response
strategies and policies.
FW-1321
Message
<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of Management Server (MS) violations has fallen below the low boundary. MS
violations indicate that an MS access request has been received from an unauthorized World Wide
Name (WWN). The MS_POLICY contains a list of WWNs of device ports that are allowed to access the
Management Server functionality.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
5
FW-1319
491

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents