Brocade Communications Systems StoreFabric SN6500B Reference page 876

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
SYSM-1001
SYSM Messages
SYSM-1001
Message
No memory.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates the switch has run out of system memory.
Recommended
Run the memShow command to view the switch memory usage.
Action
Reboot or power cycle the switch.
Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
SYSM-1002
Message
<number>, Switch: <Switch number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates a user has executed either the switchShutdown or switchReboot command. All services are
brought down for a logical switch.
Recommended
No action is required if the switchShutdown or switchReboot command was executed intentionally. If
Action
the switchShutdown command was run, you must run the switchStart command to restart traffic on the
logical switch.
SYSM-1003
Message
<number>, Switch: <start reason>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the user executed the switchStart or switchReboot command. All services are brought back
up after a temporary shutdown of the logical switch.
Recommended
No action is required if the switchStart command was executed intentionally. Because reinitializing a
switch is a disruptive operation and can stop I/O traffic, you may have to stop and restart the traffic during
Action
this process.