Enabling A Raslog Message Or Module; Setting The Severity Level Of A Raslog Message; Displaying System Message Logs And Attributes - Brocade Communications Systems StoreFabric SN6500B Reference

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

Enabling a RASLog message or module

To enable a single RASLog message or all messages in a module that were previously disabled,
perform the following steps.
1. Log in to the switch as admin.
2. Use the following commands to enable a single RASLog message or all messages that belong

Setting the severity level of a RASLog message

To change the default severity level of a RASLog message, perform the following steps.
1. Log in to the switch as admin.
2. Use the rasadmin --set -log message_ID -severity [DEFAULT | INFO | WARNING | ERROR |
3. Use the rasadmin --show -severity message_ID command to verify the severity of the message.

Displaying system message logs and attributes

This section provides information on displaying the system message logs. These procedures are
valid for all the supported platforms.
Fabric OS Message Reference
53-1002749-01
to a module:
Execute the rasadmin --enable -log messgae_ID command to enable a single RASLog
message that has been disabled.
For example, execute the following command to enable BL-1001 message that was
previously disabled.
switch:admin> rasadmin --enable -log BL-1001
2012/10/15-13:24:30, [LOG-1006], 373, SLOT 4 | CHASSIS, INFO, switch, Log
message BL-1001 has been enabled.
Use the rasadmin --show -log messgae_ID command to verify the status of the message.
Execute the rasadmin --enable -module module_ID command to enable all messages in a
module. For example, execute the following command to enable to all previously disabled
BL messages.
switch:admin> rasadmin --enable -module BL
2012/10/15-13:28:37, [LOG-1007], 375, SLOT 4 | CHASSIS, INFO, switch, Log
Module BL has been enabled.
Use the rasadmin --show -module module_ID command to verify the status of the
messages that belong to a module.
CRITICAL] to change the severity level of a message. For example, execute the following
command to change the severity level of C2-1004 message to WARNING.
switch:admin> rasadmin --set -log C2-1004 -severity WARNING
switch:admin> rasadmin --show -severity C2-1004
Message
Severity
C2-1004 :
WARNING

Displaying system message logs and attributes