RPCD-1004
Message
Invalid certificate file. Secure RPCd is disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the Secure Sockets Layer (SSL) certificate file has been corrupted.
Recommended
To enable remote procedure call daemon (RPCD) in secure mode, install a valid SSL certificate on the
Action
switch.
RPCD-1005
Message
Missing private key file. Secure RPCd is disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the private key file is missing.
Recommended
Run the secCertUtil command to install a valid private key file.
Action
RPCD-1006
Message
Permission denied accessing private key file. Secure RPCd is disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the private key file configured on the switch could not be accessed because the root did not
have read-level access.
Recommended
Change the file system access level for the private key file to have root read-level access.
Action
RPCD-1007
Message
Invalid private file. Secure RPCd is disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the private key file has been corrupted.