Brocade Communications Systems StoreFabric SN6500B Reference page 158

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
AN-1001
AN Messages
AN-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Check memory usage on the switch using the memShow command. Restart or power cycle the switch.
Action
AN-1002
Message
Failed to initialize; rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of the "trafd" daemon has failed.
Recommended
Download a new firmware version using the firmwareDownload command.
Action
AN-1003
Message
Latency bottleneck on port <slot number>/<port number within slot number>.
<percentage of seconds affected by latency bottlenecking> pct. of <observation
period over which the percentage of affected seconds is reported> secs. affected.
Avg. delay <observed average time between frames during affected seconds> us. Avg.
slowdown <observed throughput drop factor during affected seconds>.
Message Type
LOG | AUDIT
Class
FABRIC
Severity
WARNING
Probable Cause
For an F_Port, indicates that the attached device is slow in responding to frames going out of the
specified port. This latency may be inherent in the device or due to heavy workload on the device.
For a long-distance E_Port, may indicate too few credits for the distance. For a non-long-distance
E_Port, indicates latency produced by a device downstream of the E_Port and is an indication of
back-pressure produced by that latency.
136
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents