Brocade Communications Systems StoreFabric SN6500B Reference page 342

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FABR-1054
FABR-1054
Message
Rebooting the standby as it received an update before port [<Port Number>] is
expanded.
Message Type
LOG | FFDC
Severity
INFO
Probable Cause
Indicates that the standby control processor (CP) did not have the port because the port expand
operation is still in progress and the standby CP has received a port update. The standby CP reboots
automatically to ensure sync and attain the normal state. This is a rare occurrence.
Recommended
No action is required.
Action
FABR-1055
Message
F_Port trunking cannot be enabled on the slot <Slot Number> port <Port Number> due
to inconsistent port configuration.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified F_Port is unable to join its assigned trunk area group because of mismatch in
the port configuration with the other trunk area members.
Recommended
Check the configuration of the port with all other ports intended to be part of the same trunk group. Use
Action
the porttrunkarea --show to identify the trunk members of the specified F_Port and the portcfgshow
command to identify the conflicting configuration between the trunk members.