Brocade Communications Systems StoreFabric SN6500B Reference page 386

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FCR-1069
FCR-1069
Message
The FC Routing service is enabled.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the FC Routing service is enabled. This is caused by the fosConfig –-enable fcr or the
configDownload command with the fcrState set to 1 (enabled). Note that the FC Routing service is
disabled by the factory.
Recommended
No action is required.
Action
FCR-1070
Message
The FC Routing configuration is set to default.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the FC Routing configuration is set to the default by the user. This removes all prior FC
Routing configurations.
Recommended
No action is required.
Action
FCR-1071
Message
Port <port number> is changed from non FCR port to FCR port.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the port became an EX_Port or VEX_Port.
Recommended
No action is required.
Action
364
Fabric OS Message Reference
53-1002749-01