Brocade Communications Systems StoreFabric SN6500B Reference page 911

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

ZEUS Messages
ZEUS-1001
Message
Port <port number> port fault. Change the SFP or check cable.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
Action
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.
ZEUS-1002
Message
Port <port number> chip faulted due to internal error.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All ports on the blade or switch will be disrupted.
Recommended
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
Action
recover a non-bladed system, execute the fastBoot command on the switch.
ZEUS-1003
Message
S<slot number>,C<chip index>: HW ASIC Chip error type = 0x<chip error type>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Reboot the system at the next maintenance window. If the problem persists, replace the blade.
Action
Fabric OS Message Reference
53-1002749-01
5
ZEUS-1001
889

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents