5
ANV-1001
ANV Messages
ANV-1001
Message
Port <port number> port fault. Change the SFP or check the cable.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
Action
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable, if
necessary.
ANV-1002
Message
Port <port number> chip faulted due to an internal error.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All the ports on the chip will be disrupted.
Recommended
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
Action
recover a non-bladed system, execute the fastBoot command on the switch.
ANV-1003
Message
S<slot number>,C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>,
Error = <chip error string>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Restart the system at the next maintenance window. If the problem persists, replace the blade.
Action
140
Fabric OS Message Reference
53-1002749-01
Need help?
Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?
Questions and answers