Brocade Communications Systems StoreFabric SN6500B Reference page 856

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
SULB-1017
Recommended
Run the firmwareDownloadStatus command for more information.
Action
Refer to the Fabric OS Troubleshooting Guide for troubleshooting information.
SULB-1017
Message
Firmwaredownload failed in slot <Slot number>.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
ERROR
Probable Cause
Indicates that the firmwareDownload command failed on the specified blade. The error may be caused
by the inconsistent application processor (AP) blade firmware stored on the active CP. It may also be
caused by an internal Ethernet issue or by a persistent storage hardware failure.
Recommended
Run the slotShow command. If the blade is in the FAULTY state, run the slotPowerOff and
Action
slotPowerOn commands to trigger another firmware download. If the blade is stuck in the LOADING
state, remove and re-insert the blade to trigger another firmware download. If the problem persists,
contact your switch service provider.
SULB-1018
Message
Firmwaredownload timed out in slot <Slot number>.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
ERROR
Probable Cause
Indicates that there may be error caused by the blade initialization issue after the new firmware is
downloaded and the blade is rebooted. The error may also be caused by an internal Ethernet issue or by
a persistent storage hardware failure.
Recommended
Run the slotShow command. If the blade is in the FAULTY state, run the slotPowerOff and
Action
slotPowerOn commands to trigger another firmware download to the blade. If the blade is stuck in the
LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem
persists, contact your switch service provider.