HIL-1104
Message
Blower <blower number> faulted, <nominal voltage> (<measured voltage>) is below
threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the fan voltage is below threshold.
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are
seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
HIL-1105
Message
Switch error, <nominal voltage> (<measured voltage>) above threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the switch voltage is above threshold. This message is specific to non-bladed switches.
Recommended
For switches that do not have field-replaceable units (FRUs), replace the entire switch.
Action
If the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the
entire switch.
HIL-1106
Message
Switch error, <nominal voltage> (<measured voltage>) below threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the switch voltage is below threshold. This message is specific to non-bladed switches.
Recommended
For switches that do not have field-replaceable units (FRUs), replace the entire switch.
Action
If the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the
entire switch.