SYSM-1004
Message
Failed to retrieve current chassis configuration option, ret=<Unknown>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates there was a failure to read configuration data from the World Wide Name (WWN) card.
Recommended
Verify that the WWN card is present and operational and the affected control processor (CP) is properly
Action
seated in its slot.
SYSM-1005
Message
CP blade in slot <Slot number> failed to retrieve current chassis type.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates there was a failure to read the chassis type from the system.
Recommended
Verify the control processor (CP) blade is operational and is properly seated in its slot.
Action
SYSM-1006
Message
CP blade in slot <Slot number> is incompatible with the chassis type.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates this chassis type is not compatible with the control processor (CP) blade.
Recommended
Use the CP blade on a compatible chassis.
Action