FCR-1066
Message
Fabric on port <port number> has the same fabric ID as another fabric.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that either the fabric split, or there is another fabric (possibly the backbone) that has the same
fabric ID as the fabric connected to the specified port.
Recommended
If the fabric split, merge the fabrics and manually re-enable the port.
Action
If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport or
portcfgVExport commands.
FCR-1067
Message
Zone configurations, total LSAN zones and aliases, exceeded on port <port number>
by <overflow> entries; max entries: <LSAN zone limit>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the total number of zone configurations created in connected fabric exceeds the maximum
number supported by the Fibre Channel.
The limit includes both active and configured information that is part of be zoning database in the edge
fabric. Non-LSAN zones are not counted in the limit.
Recommended
Limit the logical storage area network (LSAN) zoning-related zone configuration in the edge fabric
Action
connected to this port.
FCR-1068
Message
The FC Routing service is disabled.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the FC Routing service is disabled. This is caused by issuing the fosConfig –-disable fcr,
configDefault, or the configDownload command with the fcrState set to 2 (disabled). Note that the FC
Routing service is disabled by the factory.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
5
FCR-1066
363