Brocade Communications Systems StoreFabric SN6500B Reference page 380

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FCR-1048
Recommended
No action is required.
Action
FCR-1048
Message
On EX port (<port number>) setting port <credit type> credits failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the indicated credit type was not set. Setting port credits failed.
Recommended
Execute the portEnable command.
Action
If the problem persists, reboot the switch.
If the message persists, collect switch information using the supportSave command, and contact your
switch service provider.
FCR-1049
Message
EX_Port (<port number>) received an ELP command that is not supported.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an incoming exchange link parameter (ELP) command that is not supported.
Recommended
Use the portEnable and portDisable to enable or disable the port.
Action
If the problem persists, contact your switch service provider.
FCR-1053
Message
Port <port number> was disabled, <disable reason>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port was disabled because of a mismatched configuration parameter.
Recommended
Use the specified disable reason to identify a possible configuration parameter mismatch between the
Action
EX_Port and the switch at the other end of the link.