5
SPC-2007
SPC-2007
Message
S<slot number containing Encryption Engine>, <module name>: Crypto post tests
success: 0x<Reason>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that Crypto Power-On Self-Test (POST) has passed successfully.
Recommended
No action is required.
Action
SPC-2008
Message
S<slot number containing Encryption Engine>, <module name>: Vader/OB1 recovered
from error.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the Crypto error from FPGA is de-asserted.
Recommended
No action is required.
Action
SPC-2009
Message
S<slot number containing Encryption Engine>, <module name>: Tamper event: User
zeroization.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the tamper event triggered due to a user zeroize request. The encryption engine is
zeroized.
Recommended
Execute the cryptocfg --initEE and cryptocfg --regEE commands.
Action