TABLE 9
Upgrade state
SUS_ACT_FWC_BEGIN
SUS_PEER_RESTORE_BEGIN
SUS_SBY_RESTORE_BEGIN
SUS_PEER_FWC_BEGIN
SUS_PEER_FS_CHECK1
SUS_FINISH
SUS_COMMIT
Recommended
Run the firmwareDownloadStatus command for more information.
Action
In a modular switch, when the firmwareDownload command fails, the command will synchronize the
firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this
operation completes (about 10 minutes) before attempting another firmware download.
In a modular switch, when the firmwareDownload command fails, the two CPs may end up with
different versions of firmware and they may not gain high availability (HA) sync. In this case, run the
firmwareDownload -s command to upgrade the firmware on the standby CP to the same version as the
active CP. Then retry the firmwareDownload command to download the desired version of firmware
onto the CPs.
Refer to the Fabric OS Troubleshooting Guide for troubleshooting information.
SULB-1010
Message
Firmwarecommit failed (status=0x<error code>).
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
INFO
Probable Cause
Indicates that the firmwareCommit command failed. The error code provides debugging information.
Recommended
If the failure is caused by an inconsistent filesystem, contact your switch service provider.
Action
SULB-1011
Message
Firmwaredownload command failed. <error string>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the firmwareDownload command failed. The error string value indicates the reason for
failure.
Fabric OS Message Reference
53-1002749-01
Upgrade state and code value (Continued)
5
SULB-1010
Code
0x2f
0x30
0x31
0x32
0x33
0x34
0x35
833
Need help?
Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?
Questions and answers