FCR-1060
Message
EX_Port(<port number>) has an incompatible configuration setting.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is
negotiating in R_RDY mode. The fabric might not form properly.
Recommended
Check the configuration on the local switch using the portCfgShow command to verify that the VC Link
Action
Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY mode.
FCR-1061
Message
Backbone fabric created on port <port number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a backbone fabric was built on the specified port.
Recommended
No action is required.
Action
FCR-1062
Message
Port <port number> disabled, system only supports <maximum ports> EX/VEX_ports.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the maximum number of supported EX_Ports or VEX_Ports was exceeded. To enable the
specified port, disable any other operational port and then re-enable the port.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
VC_RDY mode: Virtual channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol,
that uses R_RDY primitive for flow control.