5
SPC-3011
SPC-3011
Message
S<slot number containing Encryption Engine>, <module name>: Persistent data
storage error: <SP status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3>
<KEK octet 4>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an attempt to store CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.
Recommended
Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
Action
needed primary and secondary KEKs.
SPC-3012
Message
S<slot number containing Encryption Engine>, <module name>: Persistent data
retrieval error: <SP status code>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an attempt to read CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.
Recommended
Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
Action
needed primary and secondary KEKs.
SPC-3013
Message
S<slot number containing Encryption Engine>, <module name>: SEK generation
failure: <SP status code>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the CryptoModule internal Secret Encryption Key could not be generated.
Recommended
Contact your switch service provider for assistance.
Action
788