5
CVLM-1008
Recommended
Run the cryptocfg --commit command again.
Action
CVLM-1008
Message
The member (<EE node WWN> <EE slot num>) of HAC (<HAC name>) is not in the fabric.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the member of the HA cluster (HAC) is not in the fabric.
Recommended
Check the inter-switch link (ISL) port connected to the fabric.
Action
CVLM-1009
Message
The member (<EE node WWN> <EE slot num>) of HAC (<HAC name>) is in the fabric.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the member of the HA cluster (HAC) is found in the fabric.
Recommended
No action is required.
Action
CVLM-1010
Message
The IP address of EE (<EE node WWN> <EE slot num>) IO link is not configured.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the IP address of the encryption engine IO link is not configured.
Recommended
Configure the encryption engine IO link IP address using the ipAddrSet command.
Action