5
C2-1013
C2-1013
Message
S<slot number>,P<port number>(<blade port number>): Duplicate rte_tbl_select
detected.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the selected table is corrupted.
Recommended
This message must have a matching message for the other duplicate table. Reset both the specified
Action
ports. If it is a trunk, reset the entire trunk.
C2-1014
Message
Link Reset on Port S<slot number>,P<port number>(<blade port number>) vc_no=<vc
number> crd(s)lost=<Credit(s) lost> <Source of link reset > trigger.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that one or more credits are lost and the link is reset.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
C2-1015
Message
Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port is re-initialized due to link reset failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.