Brocade Communications Systems StoreFabric SN6500B Reference page 209

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

C2 Messages
C2-1001
Message
Port <port number> port faulted due to SFP validation failure. Check if the SFP is
valid for the configuration.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
Action
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.
C2-1002
Message
Port <port number> chip faulted due to an internal error.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All the ports on the blade or switch will be disrupted.
Recommended
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
Action
recover a non-bladed system, execute the fastBoot command on the switch.
C2-1004
Message
S<slot number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Restart the system at the next maintenance window. If the problem persists, replace the blade.
Action
Fabric OS Message Reference
53-1002749-01
5
C2-1001
187

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents