Recommended
Wait a few minutes and try the command again.
Action
SEC-1166
Message
Non FCS tries to commit failover.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1167
Message
Another FCS failover is in process. Command terminated.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that because another failover is already in progress, this failover attempt cannot proceed.
Recommended
Verify the security event was planned. If the security event was planned, retry fabric configuration server
Action
(FCS) failover after the current failover has completed, if this switch should become the primary FCS. If
the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1168
Message
Primary FCS failover is busy. Please retry later.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
Fabric OS Message Reference
53-1002749-01
5
SEC-1166
727
Need help?
Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?