CVLM-1011
Message
The HAC failover occurs at EE (<EE node WWN> <EE slot num>).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the HA cluster (HAC) failover occurs at the encryption engine.
Recommended
No action is required.
Action
CVLM-1012
Message
The HAC failback occurs at EE (<EE node WWN> <EE slot num>).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the HA cluster (HAC) failback occurs at the encryption engine.
Recommended
No action is required.
Action
CVLM-1013
Message
Redirect zone create failed because no Host/Target
(<HostPortWWN>/<TargetPortWWN>) L2 zone exists.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that creation of the redirect zone has failed.
Recommended
Create the Layer 2 zone for host and target and run the cryptocfg --commit command again.
Action
Fabric OS Message Reference
53-1002749-01
5
CVLM-1011
261