Brocade Communications Systems StoreFabric SN6500B Reference page 684

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
PS-1006
PS-1006
Message
Failed to add fabricmode toptalker monitors on domain=<domain id>, because
end-to-end monitors are configured on this switch.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that end-to-end monitors are configured on the switch.
Recommended
Delete end-to-end monitors on the switch and re-install the fabric mode Top Talker monitor. End-to-end
Action
monitors and fabric mode Top Talker monitors are mutually exclusive.
PS-1007
Message
Failed to add Fabricmode Top Talker on domain=<domain id>. <function name>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that FC Routing (FCR) is enabled on the specified fabric.
Recommended
Top Talker cannot be installed on a fabric with FCR service enabled. In case Top Talker must be installed
Action
on a fabric, disable FCR using the fosconfig --disable fcr command.
PS-1008
Message
Failed to delete fabricmode Top Talker monitor on domain <domain id>, Failure
reason: <error code>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the fabric is not stable, the domain is not reachable, or the resource is not available.
Recommended
Wait for the fabric to become stable and then execute the perfttmon --delete fabricmode command.
Action
662
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents