Message
F_Port <Port that was reset> was reset because a WWN mapped device using it,
through N_Port <Port who's state change caused the reset>, went offline.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified F_Port was reset because an N_Port went offline and the changes need to be
propagated to all involved devices.
Recommended
No action is required. This port reset was not an error.
Action
AG-1040
Message
PID of the devices connected to Port <port number> may have changed, as the port
was toggled. Check EE monitor configuration as it might not be functional.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that N_Port ID virtualization (NPIV) assigns a new port ID (PID) each time the same port is
disabled and then re-enabled. As the PID has changed, the end-to-end (EE) monitors installed with the
previous PID stops functioning.
Recommended
Install new EE monitors with the new PID of the port to be monitored by using the perfAddEEMonitor
Action
command.
AG-1041
Message
Static F_Ports mapped to N_Port <port number> are disabled as Trunking is enabled
on the N_Port.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a trunk is enabled on the specified N_Port, and therefore the F_Port static mapping is
disabled.
Recommended
Delete static mapping on the Access Gateway using the ag --staticdel command or disable the trunk on
Action
the N_Port using the switchCfgTrunkPort command.