5
SEC-1031
SEC-1031
Message
Current security policy DB cannot be supported by standby. CPs will go out of
sync.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the security database size is not supported by the standby control processor (CP).
Recommended
Reduce the security policy size by deleting entries within a policy or by deleting some policies.
Action
SEC-1032
Message
Empty FCS list is not allowed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1033
Message
Invalid character used in member parameter to add switch to SCC policy; command
terminated.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a member parameter in the secPolicyAdd command is invalid (for example, it may include an
invalid character, such as an asterisk). A valid switch identifier (a WWN, a domain ID, or a switch name)
must be provided as a member parameter in the secPolicyAdd command. Only the secPolicyCreate
command supports use of the asterisk for adding switches to policies.
Recommended
Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to
Action
add specific switches to the Switch Connection Control (SCC) policy.