FCOE-1029
Message
Version mismatch between FIP FDISC and root VN port.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates a version mismatch between the fabric login (FLOGI) and FDISC.
Recommended
It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance.
Action
FCOE-1030
Message
Version mismatch between FIP LOGO and root VN port.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates a version mismatch between the FCoE initialization protocol (FIP) logout and the base fabric
login (FLOGI).
Recommended
It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance.
Action
FCOE-1031
Message
FCoE port deleted port <port> slot <slot>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that an FCoE port has been deleted.
Recommended
No action is required.
Action
FCOE-1032
Message
We are in WARM RECOVERING state...
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that high availability (HA) failover or switch reboot may be in progress.