Recommended
No action is required.
Action
SEC-1183
Message
Policy to binary conversion error: Port <port number> is out range.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a security database conversion has failed because of an invalid value.
Recommended
Retry the command with a valid value.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
SEC-1184
Message
<Security server (RADIUS/LDAP/TACACS+)> configuration change, action <action>,
server ID <server name>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified action is applied to the specified remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) server configuration. The possible actions are ADD, REMOVE, CHANGE,
and MOVE.
Recommended
No action is required.
Action
SEC-1185
Message
<action> switch DB.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the switch database was enabled or disabled as the secondary authentication, accounting, and
authorization (AAA) mechanism when the remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) is the primary AAA mechanism.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
5
SEC-1183
731