FABR-1051
Message
D-Port <Testname> test failed for slot <Slot> and port <Port>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the D_Port test failed for the given slot and port due to one of the following reasons:
Recommended
Replace the faulty SFPs, cables, or blade.
Action
FABR-1052
Message
The configured port speed (16G/10G on non FC16 blade or 1G on FC16 blade) is
invalid. Persistently disabling port <Port that is being disabled>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the configured speed (16 Gbps or 10 Gbps on the non-FC16 blade or 1 Gbps on the FC16
blade) for the specified port is invalid.
Recommended
Execute the portCfgSpeed command to change the port speed.
Action
FABR-1053
Message
The switch is disabled due to an inconsistency found in the interop config
parameters.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the configuration keys have interopmode parameters such as switch.interopMode and
switch.mcdtFabricmode set.
Recommended
Execute the interopmode command to reset the parameters.
Action
Fabric OS Message Reference
53-1002749-01
The small form-factor pluggable (SFP) fault detected by electrical loopback test failure.
The cable fault detected by optical loopback test failure.
An application-specific integrated circuit (ASIC) issue detected by link traffic test failure.
5