5
CNM-1001
CNM Messages
CNM-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Check memory usage on the switch using the memShow command.
Action
Restart or power cycle the switch.
CNM-1002
Message
Failed to initialize <module> rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within the Cluster Node Manager (CNM) has failed.
Recommended
Download a new firmware version using the firmwareDownload command.
Action
CNM-1003
Message
Crypto device cfg between local switch (<local domain id>) and peer (<peer domain
id>) out of sync. New encryption session not allowed.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the encryption engine nodes in the cluster encryption group have different configurations.
Recommended
Synchronize the configuration in the cluster group using the cryptocfg command.
Action