Examples
To create a configuration containing three zones:
switch:admin> cfgShow
Defined configuration:
cfg:
zone:
zone:
zone:
alias: array1
alias: array2
alias: loop1
switch:admin> zoneObjectExpunge "White_zone"
switch:admin> cfgShow
Defined configuration:
cfg:
zone:
zone:
alias: array1
alias: array2
alias: loop1
See also
cfgAdd
cfgClear
cfgDelete
cfgDisable
cfgEnable
cfgRemove
cfgSave
cfgShow
zoneObjectCopy
zoneObjectRename
USA_cfg
Red_zone; White_zone; Blue_zone
Blue_zone
1,1; array1; 1,2; array2
Red_zone
1,0; loop1
White_zone
1,3; 1,4
21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df
USA_cfg
Red_zone; Blue_zone
Blue_zone
1,1; array1; 1,2; array2
Red_zone
1,0; loop1
21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df