HP StorageWorks 2/64 - Core Switch Command Reference Manual page 268

Hp storageworks fabric os 5.x command reference guide (aa-rvhvb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

Examples
To change the FRU state alert configuration:
switch:admin> fwfrucfg
The current FRU configuration:
-----------------------------------------------
Power Supply
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0] 3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed
See also
fwConfigure
fwMailCfg
268 Fabric OS commands