historyShow
Displays the entire field replaceable unit (FRU) history log.
Synopsis
historyshow
Availability
all users
Description
Use this command to display the entire history log, which records insertion and removal events for blades,
power supplies, fans, and world wide name (WWN) cards. Each history record contains three lines of
information. The first line of each record contains the following:
Object type
Object number
Event type
Time of the event
The second and third lines of a record respectively contain the factory part number and factory serial
number, if applicable:
Factory Part Number
Factory Serial Number
Operands
none
296 Fabric OS commands
CHASSIS, FAN, POWER SUPPLY, SW BLADE (port blade), CP
BLADE (control processor), WWN (WWN card), or
UNKNOWN
Slot number for blades and unit number for everything else.
Inserted, Removed, or Invalid
Format: Day Mon dd hh:mm:ss yyyy
xx-yyyyyyy-zz or Unknown
xxxxxxxxxxxx or Unknown