cfgEnable

Enables a zone configuration.
Synopsis
cfgenable "cfgName"
Availability
admin
NOTE:
This command requires HP Advanced Zoning, which is included within the Base Configuration
Services and bundled with each B-series switch.
Description
Use this command to enable a zone configuration. The specified zone configuration is built by checking
for undefined zone names, zone alias names, or other inconsistencies by expanding zone aliases,
removing duplicate entries, and then installing the current configuration.
If the build fails, the previous state is preserved (zoning remains disabled, or the previous configuration
remains in effect). If the build succeeds, the new configuration replaces the previous configuration. See the
command for a description of defined and current configurations.
cfgShow
NOTE:
When security is enabled, this command can be issued only from the primary FCS switch.
Operands
This command has the following operand:
cfgName
Examples
To enable the zone configuration "USA_cfg":
switch:admin> cfgenable "USA_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'USA_cfg' configuration
zone config "USA_cfg" is in effect
Updating flash ...
See also
cfgClear
cfgDisable
cfgSave
cfgShow
Specify the name of a zone configuration to enable, in quotation
marks. This operand is required.
(yes, y, no, n): [no] y