switchStatusPolicySet
Sets the policy parameters that determine overall switch status.
Synopsis
switchstatuspolicyset
Availability
admin
Description
Use this command to set policy parameters for calculating the overall status of the switch enclosure. The
policy parameter values determine how many failed or faulty units of each contributor are allowed before
triggering a status change in the switch from HEALTHY to MARGINAL or DOWN. The status of the switch
can be found by issuing the
PowerSupplies, WWN, CP, and Blade, might differ from platform to platform.
The command displays the current parameters in a three-column table format, shown in
command then prompts the user to change the values for each policy parameter. The default values for
the policy parameters are in shown
Table 18
Default contributor, values, and status
Contributor
PowerSupplies
Temperatures
Fans
WWN
CP
Blade
Flash
MarginalPorts
FaultyPorts
MissingSFPs
Any single contributor can force the overall status of the switch to MARGINAL or DOWN. For example,
assuming that the switch contributor values are set to the default values, if there is one faulty port in a
switch, then this contributor would set the overall switch status to MARGINAL. If two ports were faulty,
then this contributor would set the overall switch status to DOWN.
Operands
none
696 Fabric OS commands
command. The existence of policies, such as Fans,
switchStatusShow
Table
18.
DOWN default
2
2
2
0
0
0
0
2
2
0
Table
MARGINAL default
1
1
1
1
1
1
1
1
1
0
18. The