HP StorageWorks 2/64 - Core Switch Command Reference Manual page 130

Hp storageworks fabric os 5.x command reference guide (aa-rvhvb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

Examples
To set the configuration parameters for a switch:
switch:admin> configure
Configure...
Fabric parameters(yes, y, no, n): [no] yes
Domain:(1..239) [1]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000] 5000
WAN_TOV: (0..30000) [0] 0
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0] 1
Disable Device Probing: (0..1) [0]
Switch PID Format: (1..2) [1]
Per-frame Route Priority: (0..1) [0]
BB credit: (1..16) [16]
Insistent Domain ID Mode (yes, y, no, n): [no]
Virtual Channel parameters(yes, y, no, n): [no] yes
VC Priority 2: (2..3) [2]
VC Priority 3: (2..3) [2]
VC Priority 4: (2..3) [2]
VC Priority 5: (2..3) [2]
VC Priority 6: (2..3) [3]
VC Priority 7: (2..3) [3]
Switch Operating Mode (yes, y, no, n): [no] yes
Interoperability Mode: (0..1) [0]
Zoning Operation parameters (yes, y, no, n): [no] yes
Disable NodeName Zone Checking: (0..1) [0]
RSCN Transmission Mode (yes, y, no, n): [no] yes
End-device RSCN Transmission Mode
(0 = RSCN with single PID, 1 = RSCN with multiple PIDs, 2 = Fabric
RSCN): (0..2) [0]
(continued on next page)
130 Fabric OS commands