HP StorageWorks 2/64 - Core Switch Command Reference Manual page 265

Hp storageworks fabric os 5.x command reference guide (aa-rvhvb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

Examples
To configure thresholds:
switch:admin> fwconfigure
1 : Environment class
2 : SFP class
3 : Port class
4 : Fabric class
5 : E-Port class
6 : F/FL Port (Optical) class
7 : Alpa performance Monitor class
8 : EE performance Monitor class
9 : Filter performance Monitor class
10 : Security class
11 : Resource class
12 : Quit
Select a class => : (1..12) [1] 1
1 : Temperature
2 : Fan
3 : Power Supply
4 : return to previous page
Select an area => : (1..4) [4] 1
Index ThresholdName
===========================================================================
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5]
switch:admin> fwconfigure --disable --port 1
LastEvent
1
envTemp001
started
10:28:59 on 02/01/2000
2
envTemp002
started
10:28:59 on 02/01/2000
3
envTemp003
started
10:28:59 on 02/01/2000
4
envTemp004
started
10:28:59 on 02/01/2000
5
envTemp005
started
10:28:59 on 02/01/2000
Status
CurVal
LastEventTime
LastVal
enabled
enabled
enabled
enabled
enabled
Fabric OS 5.x command reference guide 265
LastState
33 C
0 C
Informative
34 C
0 C
Informative
36 C
0 C
Informative
35 C
0 C
Informative
36 C
0 C
Informative