Examples
To run a functional test on slot 1 using external (SERDES) loopback:
switch:admin> minicycle --slot 1 -lb_mode 2
Running minicycle ..............
One moment please ...
Path 0 ... Spinning ...
Path 1 ... Spinning ...
Path 2 ... Spinning ...
Path 3 ... Spinning ...
Path 4 ... Spinning ...
Path 5 ... Spinning ...
Path 6 ... Spinning ...
Path 7 ... Spinning ...
Test Complete: minicycle Pass 1 of 1
Duration 0 hr, 1 min & 4 sec (0:1:4:409).
passed.
To run a functional test on ports 0, 1, 2, and 8 using port loopback:
switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1
Back Plane Loop Back mode is ON.
Running mini Cycle .............
One moment please ...
Path 0 ... Spinning ...
Path 1 ... skipped.
Path 2 ... skipped.
Path 3 ... skipped.
Path 4 ... skipped.
Path 5 ... skipped.
Path 6 ... Spinning ...
Path 7 ... Spinning ...
Test Complete: "minicycle" Pass 1 of 1
Duration 0 hr, 0 min & 23 sec (0:0:23:100).
passed.