NOTE:
This command is not supported on the HP StorageWorks 4/8 or 4/16 SAN switch, the HP
StorageWorks SAN Switch 4/32, or the HP StorageWorks 4/256 SAN Director, which use the Condor
ASIC.
Operands
This command has the following operands:
--slot slotnumber
-passcnt passcnt
-txports itemlist
-scamoff offset
-dcamoff offset
-fdefoff offset
Examples
To run a frame filter test:
switch:admin> filtertest -txports 3/1-3/3
Running filtertest ..............
Test Complete: filtertest Pass 1 of 1
Duration 0 hr, 0 min & 2 sec (0:0:2:679).
passed.
Diagnostics
When it detects failures, the subtest might report one or more of the following error messages:
DIAG-ACTTEST
DIAG-FLTINIT
DIAG-FLTRCV
DIAG-FLTXMIT
DIAG-NUMTEST
See the HP StorageWorks Fabric OS 5.x diagnostics and system error messages reference guide for more
information.
See also
itemList
238 Fabric OS commands
Specify the slot number on which the diagnostic operates. The
port specified are relative to this slot number. The default is 0
and designed to operate on fixed-port-count products.
Specify the number of times to perform this test. The default value
is 1.
Specify the user port numbers to perform this test. All user ports
are set by default.
Specify the program location to write SCAM test data in SCAM
memory. The default value is 0. The maximum offset number is
set if the specified number is larger than the limit.
Specify the program location to write DCAM test data in DCAM
memory. The default value is 0. The maximum offset number is
set if the specified number is larger than the limit.
Specify the program location to write filter test definition data in
filter definition memory. The default value is 0. The maximum
offset number is set if the specified number is larger than the
limit.