diagSetBurnin

Initializes the blade for a burn-in run.
Synopsis
diagsetburnin [--slot slotnumber][script | -current]
Availability
admin
Description
This sets up the blade burn-in parameters for the registered burn-in script. The burn-in will start at the next
run of power-on self-test (POST) on the designated blades.
The errors and activity logs are stored in flash memory. The activity log of the script is saved in
/var/log/scriptname.slot.log. The errors produced are available from the
command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at the test that
was interrupted at the time of the power cycle. This command does not require a reboot to take effect.
NOTE:
Boards must be installed prior to running this command and
diagSetBurnin
NOTE:
HP StorageWorks recommends running the burninErrClear command prior to running
diagSetBurnin
Operands
This command has the following operands:
--slot slotnumber
script
-current
Examples
To set the burn-in script and mode:
switch:admin> diagsetburnin --slot 1 -current
existing script is: /fabos/share/switchess.sh
Burnin mode is Enabled.
Removing all log files in /var/log for slot 1
Slot 1 burnin name is now /fabos/share/switchess.sh
Config update Succeeded
See also
burninErrShow
diagSetCycle
if you want to use both commands.
and diagSetCycle.
Specify which slot number to update. If this option is not
specified at all, then all slots on the switch are set up for burn-in.
Specify the name of the burn-in script to run.
Set the name of burn-in script to current burn-in script.
burninErrShow
must be run prior to
diagSetCycle
Fabric OS 5.x command reference guide 153