HP StorageWorks P9000 Manual page 98

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 35 Error codes (part code 03122) (continued)
Part
Error
Code
Number
03122
106041
03122
106042
03122
106062
03122
106063
03122
106064
03122
106078
03122
106087
03122
106090
03122
106091
03122
106093
03122
106094
03122
106095
03122
106096
03122
106097
03122
106098
98
Message (part code group 3nnn)
Error Message
There are no valid volumes, because the
pools are blocked.
The shrinking operation cannot be
performed on the specified pool.
The pool cannot be restored.
The pool cannot be restored.
The pool cannot be restored.
The specified function is not available
because the necessary program product
is not installed.
The operation cannot be done because
there is no pool that can be associated
with a Thin Provisioning volume (V-VOL).
The depletion threshold is set lower than
the warning threshold.
The warning threshold is not input.
The depletion threshold is not input.
More than one drive type is used
between the LDEVs selected for the pool
volumes. When different drive types are
used together in the same pool, the
performance will be impacted by the
lowest performing drive type. Confirm
that selected LDEVs with a mix of drive
types are OK?
The operation cannot be done because
the configuration of the specified pools
does not meet the conditions below.
The smart pool is enabled.
The tier management is in manual
operation.
Failed to get the pool information.
The operation cannot be done because
the specified pool is in monitoring
operation.
The operation cannot be done because
the specified pool is calculating the
monitor information.
Recommended Action
Restore the blocked status of the pools.
Check the pool capacity, the maximum
reserved capacity, and the current
reserved capacity, then retry the
operation.
Delete the pool.
Execute any of the following actions,
then retry the operation.
Increase the pool capacity by adding
pool volume(s).
Reduce the pool usage.
Block the pool.
Install the necessary program product.
Check the specified value of the
subscription limit, then retry the
operation.
Check the setting of depletion threshold
and warning threshold, then retry the
operation.
Check the setting of warning threshold,
then retry the operation.
Check the setting of the depletion
threshold, then retry the operation.
To continue the processing, click [OK].
Otherwise, click [Cancel].
Check the configuration of the pools.
Check the status of the pool, and then
retry the operation.
Check the status of the pool, and then
retry the operation.
Check the status of the pool, and then
retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents