Table 31 Error codes (part code 3005) (continued)
Part
Error
Error Message
Code
Number
3005
58467
The specified volume cannot be set as
a Pool-VOL, because it exceeds the
licensed capacity.
3005
58468
The emulation type of the logical
volume is incorrect.
3005
58469
The specified logical volume is being
used by another program product.
3005
58470
The operation cannot be done, because
the usage of the specified Pool is 100%
(full).
3005
58471
The shared memory for the V-VOL
management area is insufficient.
3005
58472
Acquisition of the pool information has
failed.
Pool information cannot be acquired
when:
3005
58473
An error occurred when setting the
Pool.
3005
58474
The capacity of shared memory is
insufficient or an error occurred during
SVP processing.
3005
58475
The PCB for fibre port is not installed.
3005
58491
A communication time-out error
occurred in the disk subsystem.
3005
58570
V-VOL management area is being used.
3005
58571
The specified operation cannot be
executed because the Pool-VOL is not
mounted.
3005
58572
An error occurred while communicating
with the storage system.
3005
58573
This function is not supported.
3005
58574
An error occurred while connecting to
the subsystem.
V-VOL management area is not
initialized.
V-VOL management area is not
installed.
Recommended Action
The current licensed capacity is
insufficient. Please purchase a new
license key to increase the licensed
capacity.
Specify another logical volume.
Specify another logical volume.
Add some Pool-VOL, or decrease the
snapshot data by restoring or deleting
the Snapshot pairs.
Install additional shared memory for the
V-VOL management area.
When the pool information cannot be
acquired, do the following:
Check the installation status of the
V-VOL management area, when the
V-VOL management area is not
initialized.
Check the installation status of the
V-VOL management area, when the
V-VOL management area is not
installed.
Check the error message of the logical
volume(s) in the Pool.
Check the amount of free space in Pool
management block in the Pool window.
Install additional shared memory if the
free space is insufficient.
Please contact HP Technical Support if
the capacity of shared memory is not
insufficient.
Install the PCB for fiber port, and retry
the operation.
If this problem persists, please contact
HP Technical Support.
Delete the Snapshot pair(s), then retry
the operation.
Check the Pool-VOL setting.
Wait, then retry the operation. If an error
occurred while operating the pool,
refresh the configuration by clicking
[Refresh All] on the [File] menu, then retry
the operation.
Check if the DKCMAIN and the SVP
microprogram versions are mismatched.
If this problem persists, please contact
HP Technical Support.
Severity
Level
W
W
W
W
W
W
W
E
W
E
W
W
W
E
E
Part code 3005