Table 62 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
8558
7105
8559
7105
8560
7105
8561
7105
8562
7105
8563
7105
8564
7105
8565
7105
8566
7105
8567
7105
8568
7105
8569
7105
8570
7105
8571
7105
8572
7105
8573
7105
8574
7105
8575
7105
8576
7105
8577
7105
8578
7105
8579
256 Message (part code group 7nnn)
Error Message
The command has been rejected,
because the specified volume is blocked
or used as a system disk.
The volume is being formatted.
This volume cannot be specified because
it is used as a command device.
The command code is invalid.
The command code sender is invalid.
The volume type is invalid.
The volume type is invalid.
The command code sender is invalid.
The attribute of the reserved volume is
invalid.
The number of effective lists is invalid.
The emulation type is invalid.
The command has been rejected,
because the area of the differential table
or pair table to set pairs is insufficient.
The selected volume does not exist.
The volume is already defined as a
reserved volume.
The volume is already defined as S-VOL.
The volume is defined as a source
volume for Auto LUN.
The volume is defined as a target volume
for Auto LUN.
The selected volume is not a reserved
volume.
No reserved volume is available for use.
The number of reserved volumes to be
defined exceeds the maximum.
The S-VOL is already paired with a
backup volume. Therefore, it cannot be
paired with the target volume.
No volume is defined as a reserved
volume.
Recommended Action
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as a reserved volume. Specify another
volume.
Wait until the volume is formatted, and
retry the operation.
Specify a volume that is not used as a
command device.
Please contact HP Technical Support.
If this problem persists please contact HP
Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Check the contents, and retry.
Check the contents, and retry.
Please contact HP Technical Support.
Specify the volume of the supported
emulation type.
See the section "Planning number of
pairs" in the HP StorageWorks P9000
Business Copy for Mainframe Systems
User Guide for the relation between the
number of pairs that can be created and
the shared memories.
Refresh the window, and retry the
operation.
Check the contents, and retry.
Check the contents, and retry.
Release the Auto LUN setting.
Release the Auto LUN setting.
Check the status of the volume.
Check the contents, and retry.
Stop the operation of the Reserve volume
setting, or delete the Reserve volume.
Check the contents, then retry the
operation.
Define the reserve volume, then retry the
operation.
Severity
Level
E
W
W
E
E
W
W
E
E
E
W
W
W
W
W
W
W
W
W
W
W
W